Auxiliary boiler goes to flame failure on light-off after a yard overhaul. What to check?

Ask a question
Asked 2 d ago · 1 answer
Vote

After a yard overhaul of the burner, an auxiliary boiler trips on flame failure about one start in three. What should be checked?

asked 2 d agoAdmin

1 answer

Vote

After a yard overhaul, check in this order:
- flame scanner (photocell) lens clean and correctly aligned
- ignition electrode gap and position against the maker's drawing
- nozzle size and type match the manual (yards sometimes fit other spares)
- pre-purge time and air damper position at light-off

A trip in only some starts usually points to the scanner or the ignition, not the fuel.

answered 2 d agoAdmin